#Aspen_HYSYS #Training_Course
#Aspen_HYSYS #Training_Course
11 Nov 2021, 02:48

Preliminary Design a Plate Heat Exchanger in Aspen EDR using Import from Aspen HYSYS Software .
09 Nov 2021, 00:24

#Aspen_Exchanger_Design_and_Rating
#Aspen_Exchanger_Design_and_Rating
09 Nov 2021, 00:12

6- Viewing the Results .
08 Nov 2021, 11:51

5- Defining Stream Specifications .
08 Nov 2021, 11:47

4- Defining the System Topology - Mixers & Tees .
08 Nov 2021, 11:27

3- Defining the System Topology - Pipes .
08 Nov 2021, 11:20

2- Getting Started with Hydraulics .
08 Nov 2021, 11:11

1- Introduction to Pipeline Modeling .
08 Nov 2021, 11:03

#Aspen_Hydraulic #Hydraulic_Calculation
#Aspen_Hydraulic #Hydraulic_Calculation
08 Nov 2021, 11:00

7. EDR does not consider high pressure when calculating baffle thickness and number of baffles. Why can’t you fit the same number as calculated in EDR design? Generally, there shouldn’t be an issue with high pressure units in terms of number of baffles. What might be more important here is the thickness of the tube sheets, positioning of nozzles, and the interaction of these with the baffle spacing. .
07 Nov 2021, 01:51

6. How does Aspen EDR calculate the mixed oil and water viscosities? In our research program, we have recently looked closely at modeling in this area and provided new recommendations on handling the modeling of streams with two liquid phases. If you provide property data for two liquid phases, the program will default to the new HTFS Method handling condensation somewhat differently from heating or cooling with no phase change. You may also over-ride the program selection under Input > Program Options > Methods/Correlations > General and select your preferred method for viscosity of two liquid phases .
07 Nov 2021, 01:50

5. Do multi-nozzle X-shell designs consider heat loss, based on the environment, to insulation thickness? No, it is assumed that exchangers are well insulated. .
07 Nov 2021, 01:50

4. In X shell design, what is the accuracy level in the mechanical design when shell side nozzles are more than 2? Generally, there shouldn’t be problems with the mechanical aspects of multi-nozzle X-shell designs unless the nozzles are in very close proximity. .
07 Nov 2021, 01:49

3. Before we begin, does it apply to both Division 1 & 2 of the ASME code? The mechanical calculations apply to ASME Division 1. ASME is progressively bringing together mechanical calculations so that more advanced Division 2 methods can be added to our program with each release .
07 Nov 2021, 01:49

2. How would you design and double pipe an exchanger? Under Input > Exchanger Geometry > Shells/Heads/Flanges > Shells/Heads you can select the shell type as Double Pipe (designated as “D-type”). .
07 Nov 2021, 01:49

1. Can you obtain a results report with the thermal and mechanical design combined? Currently, our Shell & Tube Thermal and Mechanical programs produce individual reports which you may tailor to your needs. .
07 Nov 2021, 01:48

Calculation Results .
07 Nov 2021, 01:48

8. What is the physical property file extension saved as? Case files are saved as .EDR files which contain all input and results for the case, including physical properties data. .
07 Nov 2021, 01:48

7. Where is the actual area vs. the required area reported on when rating an existing exchanger? You can find the area ratio on the Results Summary > Overall Summary form, and on the Thermal Hydraulic Summary > Performance form .
07 Nov 2021, 01:46