en
Feedback
Practical Process Engineering

Practical Process Engineering

Open in Telegram

Please invite your friends to follow this channel if they are interested in Process Engineering like you. Thank you in advance!

Show more
The country is not specifiedThe category is not specified
2 467
Subscribers
+1324 hours
+607 days
+22630 days
Posts Archive
To calculate above factor, you need to know the maximum amount of gas flowrate. It would be the normal operation flowrate times a surging margin based on following chart

VOLUMETRIC GAS LOAD FACTOR
VOLUMETRIC GAS LOAD FACTOR

#Separator_sizing based on #Shell_DEP Here I give you a summary of liq./vap. sizing based on Shell design practice: Vertical separator VS. Horizontal separator: Vertical separator advantages: - Smaller footprint and vessel volume - Easier solid removal -Separation efficiency is insensitice to liquid level Horizontal separator is used if: -Large liq. slugs have to be handled -Space is limited for vertical vessel head -Low liquid velocity is required Sizing steps: 1- Choose the right separator for your application 2-Size it (Diameter, Length/Height and level controls, etc.) To select proper separator, follow this instruction: 1- Calculate VOLUMETRIC GAS LOAD FACTOR 2- Calculate FLOW PARAMETER 3-Calculate SEPARATION EFFICIENCY 4-Use comparison table to compare different kind of separator and choose the one fitting your applications and demands

A-Guideline-for-Design-Pressure-Part-2.pdf2.21 KB

A-Guideline-for-Design-Pressure-Part-1.pdf1.40 KB

A guide line for design pressure- Parts 1 & 2 by Saeid Rahimi👇🏼👇🏼

Crane-Flow-of-Fluids.pdf3.39 MB

Flow of Fluids Through Valves, Fittings and Pipings, Crane Technical Paper 410- SI Edition
Flow of Fluids Through Valves, Fittings and Pipings, Crane Technical Paper 410- SI Edition

Cameron-Hydraulic-Data.pdf29.62 MB

Cameron Hydraulic Data
Cameron Hydraulic Data

Flare kDrum-Part1-Saeid Rahimi.pdf2.05 KB

Flare kDrum-Part2-Saied Rhimi.pdf1.96 KB

Flare Knock Out Drum Design- Parts 1 & 2 by Saeid Rahimi👇🏼👇🏼👇🏼

Gestra-Guide- Steam-Condensate.pdf5.44 MB

Gestra guide for steam and condensate technology, 2nd edition
+1
Gestra guide for steam and condensate technology, 2nd edition

THe best spreadsheet to calculate dimensions of pipes, flanges, blinds and fittings