en
Feedback
Marine electrical team

Marine electrical team

Open in Telegram

🚩 Channel was restricted by Telegram

Show more
The country is not specifiedTransport4 047
3 725
Subscribers
No data24 hours
-187 days
-11130 days
Posts Archive
#troubleshooting #low #insulation #eto

#vfd #electrical #eto

#oil mist detector #check #marine

#synchronise #alternator #marine #eto

#insulation #220v #440v #marine

#Earth leakage #electrical #marine

#engine #room #tour #marine #eto

#PLC #connection #guide

​​Certainly! A Programmable Logic Controller (PLC) connection guide typically provides instructions on how to establish communication between a PLC and other devices or systems. Below is a preview of what such a guide might include: PLC Connection Guide Preview 1. Introduction: Brief overview of the purpose of the guide. Importance of proper PLC connections for efficient automation. 2. Preparing the Environment: Check the power supply to the PLC. Ensure proper grounding for safety. Verify the environmental conditions (temperature, humidity) are within specified ranges. 3. Hardware Connections: Detailed instructions on connecting input and output devices to the PLC. Wiring diagrams and pin configurations. Guidelines for connecting power sources and protecting circuits. 4. Communication Protocols: Explanation of communication protocols (e.g., Modbus, Profibus). Setting up communication parameters such as baud rate and parity. Troubleshooting tips for common communication issues. 5. PLC Programming Software: Installation guide for the programming software. Steps for establishing a connection between the PLC and the programming tool. Overview of programming languages and ladder logic. 6. Network Configurations: Connecting PLCs in a network. IP addressing and subnetting for Ethernet-based communication. Virtual Local Area Network (VLAN) setup if applicable. 7. PLC to Human-Machine Interface (HMI): Connecting the PLC to an HMI for monitoring and control. Configuration steps for displaying data on the HMI. Troubleshooting tips for HMI-PLC communication. 8. Testing and Debugging: Procedures for testing the PLC connections. Debugging techniques for identifying and resolving issues. Recommended testing tools and equipment. 9. Documentation: Importance of maintaining detailed documentation for future reference. Log sheets for recording changes and configurations. Creating backup copies of PLC programs and configurations. 10. Safety Guidelines: Reminders about safety precautions during the connection process. Emergency shutdown procedures if needed. 11. Conclusion: Recap of key steps and considerations. Encouragement to seek further assistance if needed. This is just a preview, and the actual guide may include additional details based on the specific PLC model and application requirements.

Статья 1: Введение в Основы Электрических Схем В этой статье представлено введение в мир электрических схем. Обсуждаются базовые понятия, такие как ток, напряжение, сопротивление, и их взаимосвязь. Рассматриваются общие символы и обозначения, используемые в электрических схемах. Читатель узнает, как распознавать основные компоненты схем и понимать их функциональность. https://telegra.ph/Master-klass-Kak-chitat-ehlektricheskuyu-shemu-kak-professional-02-18 #electrical #drawing #ru

Auxiliary engine switch board #ETO #electrical #drawing
Auxiliary engine switch board #ETO #electrical #drawing

​​Conductivity of Water Electrical conductivity is an indicator of water quality. Conductivity data can determine concentration of solutions, detect contaminants and determine the purity of water. YSI conductivity sensors measure conductivity by AC voltage applied to nickel electrodes. These electrodes are placed in a water sample (or other liquid), where the current flows through the electrodes and the sample. Current level has a direct relationship with the conductivity of the solution. Conductivity is the ability of a material to conduct electrical current. The principle by which instruments measure conductivity is simple - plates/wires are placed in the sample, a potential is applied across them (normally a sine wave voltage), and the current is measured. Conductivity, the inverse of resistivity is determined from the voltage and current values according to Ohm's law. Since the charge on ions in solution facilitates the conductance of electrical current, the conductivity of a solution is proportional to its ion concentration. In some situations, however, conductivity may not correlate directly to concentration. Ionic concentrations can alter the linear relationship between conductivity and concentration in some highly concentrated solutions. The basic unit of conductivity is the siemens (S), sometimes referred to as mho. Since cell geometry affects conductivity values, standardized measurements are expressed in specific conductivity units (S/cm) to compensate for variations in electrode dimensions. Conductivity measurements, along with temperature, also allow for salinity values to be calculated through algorithms. Conductivity meters can use different types of sensors such as the non-wiped conductivity field sensor shown below. #conductivity #sensor

Time to clean salinity sensor #fwg #sasakura #fresh #water #generator
+1
Time to clean salinity sensor #fwg #sasakura #fresh #water #generator

Hello guys, sorry for such big delay with congratulations, I wish you happy new year, to all your dreams become true, thanks
Hello guys, sorry for such big delay with congratulations, I wish you happy new year, to all your dreams become true, thanks for reading of my channel, keep going, a lot of interesting will be in 2024😊 One more time, happy new year to everybody, and seven feet under the keel ✨👌

Merry Christmas!
Merry Christmas!

TTS 3542-45 CRANE (А).pdf19.79 MB

MARINE RADAR MAGNETRON CHANGING PROCEDURE.pdf1.47 KB

#radar #magnetron #jrcs #electrical
+2
#radar #magnetron #jrcs #electrical

#brunvoll #thruster

#macgregor