Ansi Protection codes
1 β Master Element
2 β Time delay Starting or Closing Relay
3 β Checking or Interlocking Relay
4 β Master Contactor
5 β Stopping
6 β Starting Circuit Breaker
7 β Rate of Change Relay
8 β Control Power Disconnecting Device
9 β Reversing Device
10 β Unit Sequence Switch
11 β Multi-function Device
12 β Overspeed Device
13 β Synchronous-speed Device
14 β Underspeed Device
15 β Speed β or Frequency, Matching Device
16 β Data Communications Device
17 β Shunting or Discharge Switch
18 β Accelerating or Decelerating Device
19 β Starting to Running Transition Contractor
20 β Electrically Operated Valve
21 β Distance Relay
22 β Equalizer Circuit Breaker
23 β Temperature Control Device
@ElecProtection
24 β Volts Per Hertz Relay
25 β Synchronizing or Synchronize-Check Device
26 β Apparatus Thermal Device
27 β Undervoltage Relay
27s- DC under voltage Relay
28 β Flame detector
29 β Isolating Contactor or Switch
30 β Annunciator Relay
31 β Separate Excitation
32 β Directional Power Relay or Reverse Power Relay
33 β Position Switch
34 β Master Sequence Device
35 β Brush-Operating or Slip-Ring Short-Circuiting Device
36 β Polarity or Polarizing Voltage Devices
37 β Undercurrent or Underpower Relay
38 β Bearing Protective Device
39 β Mechanical Condition Monitor
40 β Field (over/under excitation) Relay
41 β Field Circuit Breaker
42 β Running Circuit Breaker
43 β Manual Transfer or Selector Device
44 β Unit Sequence Starting Relay
45 βDC over voltage Relay
46 β Reverse-phase or Phase-Balance Current Relay
47 β Phase-Sequence or Phase-Balance Voltage Relay
48 β Incomplete Sequence Relay
49 β Machine or Transformer, Thermal Relay-OLR
50 β Instantaneous Overcurrent Relay
50G - Instantaneous Earth Over Current Relay (Neutral CT Method)
50N - Instantaneous Earth Over Current Relay (Residual Method)
50BF - Breaker failure
51 β AC Inverse Time Overcurrent Relay
51G- AC Inverse Time Earth Overcurrent Relay (Neutral CT Method)
51N- AC Inverse Time Earth Overcurrent Relay (Residual Method)
52 β AC Circuit Breaker
52a- AC Circuit Breaker Position (Contact Open when Breaker Open)
52b- AC Circuit Breaker Position (Contact Closed when Breaker Open)
53 β Exciter or DC Generator Relay
54 β Turning Gear Engaging Device
55 β Power Factor Relay
56 β Field Application Relay
57 β Short-Circuiting or Grounding Device
58 β Rectification Failure Relay
59 β Overvoltage Relay
60 β Voltage or Current Balance Relay
61 β Density Switch or Sensor
62 β Time-Delay Stopping or Opening Relay
63 β Pressure Switch
64 β Ground Detector Relay
64R - Restricted earth fault
64S - Stator earth fault
65 β Governor
66 β Notching or Jogging Device
67 β AC Directional Overcurrent Relay
68 β Blocking Relay
69 β Permissive Control Device
70 β Rheostat
71 β Liquid Level Switch
72 β DC Circuit Breaker
73 β Load-Resistor Contactor
74 β Alarm Relay
75 β Position Changing Mechanism
76 β DC Overcurrent Relay
77 β Telemetering Device
78 β Phase-Angle Measuring Relay or "Out-of-Step" Relay
79 β AC Reclosing Relay (Auto Reclosing)
80 β Flow Switch
81 β Frequency Relay
82 β DC Reclosing Relay
83 β Automatic Selective Control or Transfer Relay
84 β Operating Mechanism
85 β Communications,Carrier or Pilot-Wire Relay
86 β Lockout Relay/Master Trip
87 β Differential Protective Relay
88 β Auxiliary Motor or Motor Generator
89 β Line Switch
90 β Regulating Device
91 β Voltage Directional Relay
92 β Voltage and Power Directional Relay
93 β Field Changing Contactor
94 β Tripping or Trip-Free Relay( trip circuit supervisen Relay)
95 β For specific applications where other numbers are not suitable
96 β Busbar Trip Lockout relay
97 β For specific applications where other numbers are not suitable
98 β For specific applications where other numbers are not suitable
99 β For specific applications where other numbers are not suitable
150 β Earth Fault Indicator
AFD β Arc Flash Detector
CLK β Clock or Timing Source
DDR β Dynamic Disturbance Recorder
DFR β Digital Fault Recorder
DME β Disturbance Monitor Equipment
ENV β Environmental Data
HIZ β High Impedance F