ar
Feedback
Practical Process Engineering

Practical Process Engineering

الذهاب إلى القناة على Telegram

Please invite your friends to follow this channel if they are interested in Process Engineering like you. Thank you in advance!

إظهار المزيد
لم يتم تحديد البلدالفئة غير محددة
2 467
المشتركون
+1324 ساعات
+607 أيام
+22630 أيام
أرشيف المشاركات
Chemical Thermodynamics for Process Simulation, 2nd Edition.pdf16.69 MB

#Book 2019
#Book 2019

Pressure_Safety_Design_Practices.pdf15.39 MB

#Book
#Book

crr98136b.pdf3.55 MB

crr98136a.pdf4.10 MB

#Book + Annexes
#Book + Annexes

This example was a little bit challenging. I hope you got the sizing concept. In case of any questions or if you need more examples, let me know.

Simulation file including 3 pilot-operated PSV's

The calculation report for all PSV's.

Move to "Reports" tab to view and print/save reports. Four different reports are available. (Documentation Builder does not w
Move to "Reports" tab to view and print/save reports. Four different reports are available. (Documentation Builder does not work on my laptop due to some reasons)

Equivalent Length Calculation
Equivalent Length Calculation

The equivalent length in all previous calculations was 5 m for both inlet and outlet pipes. Select "Calculate Equivalent Length". Equivalent Length Calculation tables show up and you can enter the exact specificaion of the pipes and specify number of fittings. HYSYS will calculate the right equivalent length based on the data you enter. L/D's are changable, if you believe default numbers are not accurate.

Result for valve A. Please note that the outlet pipe size dropped to 24". So, if we install the 3rd PSV, the bottom line will
Result for valve A. Please note that the outlet pipe size dropped to 24". So, if we install the 3rd PSV, the bottom line will be smaller PSV plus smaller outlet pipe size. You see how software helps us add more PSV and size the lines quickly.