6. Does EDR perform special code calculation, such as those required for graphite heat exchangers? ASME has new code calculations for graphite exchangers. If the market requirement is large enough, we may add these to our mechanical products in the future. .
07 лист 2021, 01:31

5. What would be the recommended approach to modeling plate and frame heat exchangers if EDR does not have built-in plate designs from vendors such as Alfa Laval? You can use Aspen Plate Exchanger to design, rate, and simulate plate and frame, brazed plate, or welded plate type exchangers. Aspen Plate Exchanger uses our own proprietary plate heat transfer and pressure drop models and correlations. It is used by many customers as an independent evaluation of vendor designs. This can be especially critical in two-phase applications. .
07 лист 2021, 01:30

4. Can this design be applied to a solid-liquid heat exchanger? We do not currently model solid-liquid heat exchangers. .
07 лист 2021, 01:30

3. Is there an option for hairpin HX in EDR? Yes, under Input > Exchanger Geometry > Shells/Heads/Flanges > Shells/Heads. Here, you can select the shell type as Hairpin multi-tubular (we designate “M-type”). .
07 лист 2021, 01:30

2. How effective is Aspen EDR in evaluating/designing vertically oriented exchangers? The program can design, rate, or simulate vertically orientate units with the same ease and accuracy as horizontal units. .
07 лист 2021, 01:30

1. Does Aspen EDR carry out twisted tube design? Aspen Shell & Tube has links to the Koch Heat Transfer twisted tube modeling via a special “dii” module, which can be obtained from the Koch Heat transfer. When present, it links into the local shell-side and tube-side calculations of Shell & Tube to fully model a twisted tube unit. .
07 лист 2021, 01:29

Exchanger Design & Rating (EDR) Capabilities .
07 лист 2021, 01:29

6. Is the complex design, Triple Segmental, supported by TEMA? TEMA recognizes single-segmental, double-segmental, and triple-segmental baffle arrangements. If you have a large shell diameter and a large number of tubes, this can give a practical design that has a feasible baffle overlap (usually 2 or more tube rows overlap). Several of our fabricators who have been using our arrangement of triple-segmental baffles for years have had good results. .
07 лист 2021, 01:28

5. How do you anticipate and compensate for fouling pressure drop increases? If the user specifies a fouling layer thickness explicitly under Input > Program Options > Fouling the program will calculate the impact of this on hot-side and cold-side pressure drops. On the shellside, the fouling will be assumed to also block the tube-to-baffle clearance and the shell-to-baffle clearance. If you specify a process fouling, resistance, and thermal conductivity of the fouling material, the layer thickness can also be calculated. .
07 лист 2021, 01:28

4. How do you optimize a thermosiphon reboiler in an ethylene oxide process? Our research shows that the program does a very good job of predicting actual circulation rate for both vertical and horizontal thermosyphon reboilers. Two-phase flow patterns are calculated while the program checks for potential instability. .
07 лист 2021, 01:27

3. Can EDR handle a thermosyphon reboiler? Is there an example file of it? Aspen Shell & Tube Exchanger can design, rate, and simulate operation of themosyphon reboilers. The program allows you to specify the interconnecting pipework in detail (if you have that information). Simulation mode is important, as the circulation rate and the thermal performance are highly interdependent. The program can also calculate the circulation rate that will be achieved. We provide two example files for thermosiphon reboilers. These examples are installed with Aspen EDR and you can find them and other EDR Shell & Tube sample files at the following location in Windows Explorer: C:\Program Files (x86)\AspenTech\Aspen Exchanger Design and Rating V8.0\Examples\Shell&Tube. .
07 лист 2021, 01:27

2. Are there any recommendations for hydraulic aspects, optimum velocity in tubes, etc.? EDR Shell & Tube provides a full Flow Analysis including RhOV2 calculations at the Shell &Tube entrance and exit points and nozzles. Warnings will alert the user when calculated values exceed the TEMA limit. Full documentation of our flow calculations—as well as a design guide for choosing economic velocities for the tubeside and shellside streams—can be accessed with a subscription to the HTFS Research Network. Under Input > Program Options > Design Options >Process Limits the user can constrain the design search by minimum and maximum velocities. .
07 лист 2021, 01:27

1. Is there a database or recommendations for the fouling factors? Yes, we provide the recommended values for TEMA Design Fouling Resistances for Industrial Fluids, Chemical Processing, Natural Gas Processing, Oil Refining, and Water. For links to the data, open the Help menu and choose “Search for help on.” Type “TEMA Design Fouling Resistances.” .
07 лист 2021, 01:26

General Heat Exchanger Design
07 лист 2021, 01:22

Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers .
07 лист 2021, 01:22

#Aspen_Exchanger_Design_and_Rating
#Aspen_Exchanger_Design_and_Rating
07 лист 2021, 01:21

How HYSYS Calculates the LMTD for LNG Heat Exchanger .
07 лист 2021, 00:32

#Aspen_HYSYS #LMTD_Calculation
#Aspen_HYSYS #LMTD_Calculation
07 лист 2021, 00:26

6- Results Interpretation: Where to find the most important Aspen Shell & Tube Exchanger results. .
06 лист 2021, 15:39

5- Program Options: Understand Aspen Shell & Tube Exchanger program options & how they are used. .
06 лист 2021, 15:16