cookie

ما از کوکی‌ها برای بهبود تجربه مرور شما استفاده می‌کنیم. با کلیک کردن بر روی «پذیرش همه»، شما با استفاده از کوکی‌ها موافقت می‌کنید.

avatar

مراجع كيمياء حيوية

نمایش بیشتر
کشور مشخص نشده استزبان مشخص نشده استدسته بندی مشخص نشده است
پست‌های تبلیغاتی
1 861
مشترکین
اطلاعاتی وجود ندارد24 ساعت
اطلاعاتی وجود ندارد7 روز
اطلاعاتی وجود ندارد30 روز

در حال بارگیری داده...

معدل نمو المشتركين

در حال بارگیری داده...

Quality assurance: all systematic actions necessary to provide adequate confidence that laboratory services will satisfy given medical needs for patient care. Quality control: is a laboratory system for recognizing and correcting the analytical error. Precision: is a close of test results from one to another when a replication is made when a same sample (control) is used. Precision can be within run and across run. Accuracy: is a close of test results from its real value (mean) when a replication is made for a test results. Mean (x): is an average of test results represents a center or a real value (accuracy) of results. Standard deviation (SD): is an average of results variation from one to another around its real value (mean). Standard deviation can be 1SD, 2SD and 3SD. Coefficient variation (CV%): is how close the results (variation) to its mean in percentage. Sensitivity: is an ability of a method to detect an amount of a substance close to zero value. Specificity: is an ability of a method to detect only a substance is being tested. Reliability: is an ability of a method to maintain accuracy, predsion, sensitivity and specificity. Imprecision: is a calculation of mean, SD and CV% to determine a random error of an analytical method. Inaccuracy: is a comparison of two methods, one is a test method (new) another is a comparative method (old) to determine a systematic error of an analytical methods. Trueness: is a close of results average or difference average to a reference value. Bias: is an average difference of a two means between two methods represents a systematic error. Error: is an expression used to define how far the data from its real value like mean, SD and CV\% Systematic error: is an abnormal error of a real value results (accuracy) to be in one side from the mean either positively or negatively in one direction of an analytical measurements. Random error: is an abnormal error of the results variation (precision) to be very far from its mean either positively or negatively of an analytical measurements. Total error: is a sum of a desirable and undesirable results of an inaccuracy (bias) represents a systematic error and a standard deviation or CV% represent a random error between two methods compared with CLIA (clinical laboratory improvement amendments) allowable error. Allowable error: is a desirable of results that can be within an acceptable mean and variation of an analytical method or measurements is compared by CLIA. Allowable total error: is a sum of a desirable bias (systematic error) and standard deviation or CV\% (random error) of a test is defined by CLIA for an analytical method. Correlation coefficient (r): is a measurement how strong a relationship between two variables, it is a number from 0 to 1 Control: is a known of sample concentration is where targeted the areas of medical decision is made, it can be low, normal and high to detect the abnormal error. Lot number: is an small amount made from big amount and given a number. Calibrator: is a known of sample concentration can be used to build a standard curve. Calibration: is an analytical method to build a standard curve to get unknown results (patients or control) which is a correlation between y axis (principle of measurement) and x-axis concentration of a calibrator.
نمایش همه...
هرمون.pdf1.83 KB
PROTEIN ELECTRO BOOK.pdf3.86 MB
ELECTROLYTES SYSTEM BOOK.pdf2.21 KB
URINARY SYSTEM BOOK.pdf4.36 MB
HEPATIC SYSTEM BOOK.pdf5.11 MB
BLOOD GAS BOOK.pdf3.25 MB
یک طرح متفاوت انتخاب کنید

طرح فعلی شما تنها برای 5 کانال تجزیه و تحلیل را مجاز می کند. برای بیشتر، لطفا یک طرح دیگر انتخاب کنید.