The air-gap power in a 6-pole, 50 Hz induction motor is 40 kW and it's output power is 36 kW. Neglect rotational loss and calculate the torque developed (in N-m)?
Anonymous voting

What must be the turns ratio of a star-delta transformer to be connected with a 11 kV/33 kV delta-star transformer in parallel?
Anonymous voting

A synchronous motor operates at full load such that the synchronous reactance drop (IaXs) is equal to the terminal voltage per phase. If the (IaXs) drop is 30% less than the induced EMF, calculate the motor's power factor?
Anonymous voting

An alternator is connected to an infinite bus-bar and delivers rated power at 0.8 lag pf. To improve the power factor to unity, which of the following procedures will be used?
Anonymous voting

The starting current and torque of a 500 V DC shunt motor is 400 A, 500 N-m respectively. What would be the torque at a full-load speed of 300 rad/sec?
Anonymous voting

The speed of a 3-phase, SCIM, 50 Hz induction motor is 750 rpm at no-load. It's speed with full-load torque is 95% of no-load value. What would be the new speed of stator poles being changed to 6 by keeping the load torque constant?
Anonymous voting

A 100/200 V, 10 kVA transformer has a maximum regulation of 10% at full-load. This transformer offers zero regulation at 0.8 lead power factor. What would be the full-load copper loss of this transformer?
Anonymous voting

Coil span: 11 slots. Typo error

A 10 pole alternator has 120 slots in stator. Each coil has a span of 9 slots. The value of pitch factor is __
Anonymous voting

Supply frequency**

The no-load current drawn by a 11 kV, 50 Hz transformer is (1-j5) A. If the supply voltage changes to 75 Hz, the magnetizing reactance (in k-ohm) would be _
Anonymous voting

🎉 A Proud Milestone for Our Institute! 🎉 🏆 7 of our students have been selected as Executive Trainees at NPCIL through the
🎉 A Proud Milestone for Our Institute! 🎉 🏆 7 of our students have been selected as Executive Trainees at NPCIL through their GATE scores! ⚡🇮🇳 This achievement is a reflection of their hard work, consistency, and determination, along with the dedicated guidance of our faculty. 🌟 Heartiest congratulations to all the selected students! May this be the beginning of a successful and impactful career in India's nuclear power sector. To all GATE aspirants: Your dream job is possible with the right strategy, consistent preparation, and unwavering dedication. Keep believing in yourself! 💙 Thank you to every student and parent who trusts us with their dreams. We remain committed to producing more success stories. #NPCIL #ExecutiveTrainee #GATE #GATE2026 #ElectricalEngineering #Engineer #GovernmentJobs #SuccessStory #GATEPreparation #DreamJob #Electrical #FutureEngineers #ProudMoment

A 500 V DC shunt motor has a starting current of 250 A and full load current of 50 A. The mechanical power developed at full-load will be _. Neglect the rotational losses.
Anonymous voting

If the load connected on a 3-phase, 4-pole, 50 Hz induction motor is equal to it's breakdown capacity, then the operating slip will be ___. Consider the standstill rotor impedance as (1+j5) ohm/phase.
Anonymous voting

The operating slip of a 3-phase, 400 V, Y-connected, 50 Hz, 2-pole induction motor is 0.06 and it's rotor voltage per phase at this slip is 10 V. What would be the turns ratio of this motor?
Anonymous voting

The magnetizing reactance of a transformer is independent of ____
Anonymous voting

The short circuit test details of a 1000V, 20 kVA transformer is 50V, rated current, 600 W. What would be the % voltage regulation at full-load, ZPF leading power factor?
Anonymous voting