The SEL-587Z is a #multifunctional #relay primarily used for #motor #protection. Some of the protection functions it offers include:
1. Overcurrent Protection: Detects and responds to excessive current levels to prevent damage to the motor or associated equipment.
2. Ground Fault Protection: Detects ground faults and provides protection against ground fault currents, which can indicate insulation failures or other faults.
3. Thermal Protection: Monitors the temperature of the motor windings to prevent overheating and damage.
4. Undercurrent Protection: Protects against low current conditions that could indicate faults or abnormalities in the motor operation.
5. Phase Imbalance Protection: Detects imbalances in phase currents, which can indicate faults or unbalanced loads.
6. Motor Start Lockout: Prevents the motor from starting if certain predetermined conditions are not met, such as excessive current or voltage imbalances.
7. Communication-Based Protection: Utilizes communication capabilities to integrate with #SCADA systems or other control systems for enhanced monitoring and protection.
These are some of the main protection functions provided by the SEL-587Z relay, but it may offer additional features depending on the specific configuration and application requirements.
1 804
+3
Motor Fault on the crane. Troubleshooting
Greetings! Today we got a "Motor Fault" error on the cargo crane and the crane doesn't want to start. In the article we will consider the main actions of ETO when searching for and eliminating this malfunction.
The problem is quite large-scale and it can be anything related primarily to electric drives of both the main and auxiliary mechanisms of the crane. There was also a short-term accompanying signal in the ECR on AMS "low insulation 440V", which further narrowed the circle of my search.
✅ Read article ➡️ https://www.eto-engineer.com/2023/07/motor-fault-on-crane-troubleshooting.html
#motor #fault #crane #cargocrane #troubleshooting
1 804
A step-down control #transformer is a type of transformer that converts a #highvoltage to a lower voltage suitable for controlling electrical devices or equipment. It typically has more windings on the primary side (where the high voltage is applied) than on the secondary side (where the lower voltage is produced). This step-down transformation allows for safer and more efficient control of electrical systems, especially in situations where the voltage needs to be reduced for control circuits or devices. Step-down control transformers are commonly used in industrial automation, HVAC systems, lighting control, and various other applications where precise voltage regulation is required.
1 804
+1
PLC failure. The cargo crane does not start. Troubleshooting
In previous articles we looked at various problems with cargo cranes, this time a PLC failure error occurred and cargo crane does not start.
What to do in such situation and how to restore the operation of the cargo crane will be discussed in this article.
✅ Read article ➡️ https://www.eto-engineer.com/2023/09/plc-failure-cargo-crane-does-not-start.html
#cargocranes #failure #PLC #troubleshooting #cranes
1 804
#Forwardreverse #motor control is a method used to control the direction of rotation of a motor, typically in applications such as industrial machinery, conveyor belts, or electric vehicles. It involves using a control system to switch the polarity of the voltage applied to the motor, thereby changing the direction of its rotation. This can be achieved using various methods such as relays, contactors, or electronic motor controllers. The control system determines whether the motor rotates in the forward or reverse direction based on the desired operation or input from sensors.
1 804
+2
Transfer fuel pump does not start in auto mode. Most common problem
Today, the transfer fuel pump does not start in auto mode, while it works normally in manual mode (the “Auto / Manual” button on the pump control panel).
In this article we will look at the most common reason for the failure of automatic pumps operating using timers and floats.
✅ Read article ➡️ https://www.eto-engineer.com/2023/09/transfer-fuel-pump-does-not-start.html
1 804
+3
Anemometer gives false readings. Troubleshooting
Today we have a problem with the anemometer, which shows the wind speed and direction on the bridge. The readings were stuck in one direction (opposite to the wind). At this speed the wind is displayed correctly.
✅ Read article ➡️ https://www.eto-engineer.com/2023/09/the-anemometer-gives-false-readings.html
#anemometer #anemoscope #brushes #generator #synchronousmotor #troubleshooting
1 804
#Multimeter #fluke explanation
A Fluke multimeter works by measuring various electrical properties like voltage, current, and resistance in a circuit. It does this by using probes to make contact with the circuit, then displaying the measured values on its screen. Depending on the model, it may have additional features like continuity testing and capacitance measurement.
1 804
A #shortcircuit of a #capacitor occurs when there's a direct path with very low resistance between its terminals, causing a sudden discharge of electrical energy stored in the capacitor. This can lead to rapid release of energy, potentially damaging the capacitor and other components in the circuit.
1 804
A #relay is an electromechanical switch that uses an electromagnet to mechanically operate a switch. Here's how it works:
1. Electromagnet: A relay consists of a coil of wire that, when energized, generates a magnetic field around it.
2. Switch Contacts: Inside the relay, there are switch contacts that are mechanically connected to the electromagnet. These contacts can be normally open (NO), normally closed (NC), or both.
3. Activation: When an electrical current is applied to the coil (energizing the electromagnet), it creates a magnetic field. This magnetic field attracts or repels the switch contacts, depending on the relay design.
4. Switching: As the switch contacts move, they either open or close an electrical circuit, depending on the relay's configuration. For example, if the relay is normally open, it closes the circuit when energized. Conversely, if it's normally closed, it opens the circuit when energized.
5. Control: Relays are often used to control high-voltage circuits with low-voltage signals. For instance, a small electrical signal from a microcontroller or a switch can control a relay, which in turn can switch on/off much larger loads such as motors, lights, or heaters.
Overall, relays provide isolation between the control circuit and the switched circuit, allowing for safe and efficient control of electrical devices.
1 804
+3
The 220V emergency equipment transformer was tripped. Actions of the ETO on the vessel
Today we have switched off all 220V emergency equipment on the vessel, including 220V emergency lighting. In this article we will analyze the cause of this breakdown, as well as ways to find and fix the problem.
✅ Read article ➡️ https://www.eto-engineer.com/2024/05/220v-emergency-equipment-transformer-was-tripped-troubleshooting.html
#blackout #breaker #emergency #floodlight #lighting #relay #shortcircuit #transformer #troubleshooting
1 804
+3
The autotransformer was flooded with sea water. Emergency fire pump problem
Today we got low insulation of 440V on the main switchboard megohmmeter when starting the emergency fire pump.
Checking the power part of the circuit showed an insulation resistance relative to the electric motor housing of 0 MOhm. Has the motor burned out or is there a chance to restore normal operation of the mechanism?
✅ Read article ➡️ https://www.eto-engineer.com/2024/05/emergency-fire-pump-problem.html
#autotransformer #emergency #emergencyfirepump #firepump #insulationresistance #lowinsulation #lowinsulation440V #motor #troubleshooting
1 804
A #computer #mouse typically works by detecting motion and translating that into cursor movement on a computer screen. It contains sensors, usually optical or laser, that track the surface it's on and detect the mouse's movements. This information is then transmitted to the computer, which moves the cursor accordingly. Additionally, buttons on the mouse allow users to click, right-click, and scroll, sending signals to the computer to perform various actions.
1 804
#Flaring refers to the controlled burning of natural gas that cannot be processed or captured. It typically occurs at oil and gas production sites, refineries, and chemical plants. Flaring is often used as a safety measure to relieve pressure and prevent dangerous buildup of gases. However, it releases greenhouse gases into the atmosphere, contributing to climate change. Efforts are underway to reduce flaring through better infrastructure and regulatory measures.
1 804
An #induction #motor is a type of electric motor where the rotation is produced by electromagnetic induction. It operates on the principle of a rotating magnetic field inducing current in a conductive rotor, causing it to turn.
An #asynchronous #motor is another term for an induction motor. It refers to the fact that the rotor speed doesn't precisely match the rotating magnetic field, creating a time lag or slip between them, leading to the motor's rotation.
1 804
Rope slack limit switch is a limit that determines the crane rope breakage. Which of the four limits works correctly? 😅😎 #cargocrane #crane #deckcrane #limitswitch #switch
1 804
The #thermoelectric effect is the phenomenon where a temperature difference between two different conductors or semiconductors generates an electric voltage. This effect is utilized in thermoelectric generators for power generation and in thermoelectric coolers for cooling applications.
1 804
+3
UPS fail. Main engine automatic backup does not work. Kongsberg Troubleshooting
The UPS fail error occurred and the final system for protecting the main engine against automatic power failure failed. A BMS AC220V UPS FAIL alarm appeared on the alarm monitoring system in the ECR.
In this article we will analyze the sequence of actions to resolve this problem.
✅ Read article ➡️ https://www.eto-engineer.com/2024/05/ups-fail-main-engine-automatic-backup.html
#AMS #battery #battery tester #BMS #bridge #capacity #KChief #Kongsberg #mainengine #manoeuvringsystem #remoteautomaticcontrol #troubleshooting #UPS
1 804
#Computer #keyboards are input devices used to type characters and commands into a computer. They typically have alphanumeric keys, function keys, modifier keys (such as Shift, Ctrl, and Alt), and special keys (such as Enter, Backspace, and Delete). Is there something specific you'd like to know or discuss about computer keyboards?